產品介紹

product

Home / Product / Agent products / PicoScope / Oscilloscope / PicoScope 9000 Series / PicoScope 9400 Series / 2 channel (9400 Series)

PicoScope 9402-05

5 GHz
250 KS 1 TS/s

PicoScope 9400 Series specifications

  PicoScope
9404-05
PicoScope
9402-05
PicoScope
9404-16
PicoScope
9402-16
Vertical
Number of input channels 4 2 4 2
  All channels are identical and digitized simultaneously.
Analog bandwidth (–3 dB)[1] Full: DC to 5 GHz Full: DC to 16 GHz
Middle: DC to 450 MHz N/A Middle: DC to 450 MHz N/A
Narrow: DC to 100 MHz DC to 450 MHz Narrow: DC to 100 MHz DC to 450 MHz
Passband flatness Full: ±1 dB to 3 GHz Full: ±1 dB to 5 GHz
Calculated rise time (tR), typical Calculated from the bandwidth.
10% to 90%: calculated from tR = 0.35/BW
20% to 80%: calculated from tR = 0.25/BW
Full: 10% to 90%: ≤ 70 ps, 20% to 80%: ≤ 50 ps Full: 10% to 90%: ≤ 21.9 ps, 20% to 80%: ≤ 15.6 ps
Middle: 10% to 90%: ≤ 780 ps, 20% to 80%: ≤ 560 ps N/A 10% to 90%: ≤ 780 ps
20% to 80%: ≤ 560 ps
N/A
Narrow: 10% to 90%: ≤ 3.5 ns. 20% to 80%: ≤ 2.5 ns 10% to 90%: ≤ 780 ps
20% to 80%: ≤ 560 ps
10% to 90%: ≤ 3.5 ns
20% to 80%: ≤ 2.5 ns
10% to 90%: ≤ 780 ps
20% to 80%: ≤ 560 ps
Step response, typical

Full bandwidth

Overshoot: < 8%
Ringing:
±6% to 3 ns
±4% from 3 ns to 10 ns
±3% from 10 ns to 100 ns
±2% from 100 ns to 400 ns
±1% above 400 ns

Middle bandwidth

Overshoot: < 6%
Ringing:
±4% to 10 ns
±3% from 10 ns to 100 ns
±2% from 100 ns to 400 ns
±1% above 400 ns

Narrow bandwidth

Overshoot: < 5%
Ringing:
±5% to 20 ns
±3% from 20 ns to 100 ns
±2% from 100 ns to 400 ns
±1% above 400 ns

N/A
RMS noise Full: 1.8 mV, maximum, 1.6 mV, typical Full: 2.4 mV, maximum, 2.2 mV, typical
Middle: 0.8 mV, maximum, 0.65 mV, typical N/A Middle: 0.8 mV, maximum, 0.65 mV, typical N/A
Narrow: 0.6 mV, maximum, 0.45 mV, typical 0.8 mV, maximum, 0.65 mV typ. Narrow: 0.6 mV, maximum, 0.45 mV, typical 0.8 mV, maximum, 0.65 mV typ.
Scale factors (sensitivity) 10 mV/div to 250 mV/div
Full scale is 8 vertical divisions
Adjustable in a 10-12.5-15-20-25-30-40-50-60-80-100-125-150-200-250 mV/div sequence.
Also adjustable in 1% fine increments or better.
With manual or calculator data entry the increment is 0.1 mV/div.
DC gain accuracy ±2% of full scale. ±1.5% of full scale, typical
Position range ±4 divisions from center screen
DC offset range Adjustable from –1 V to +1 V in 10 mV increments (coarse). Also adjustable in fine increments of 2 mV.
With manual or calculator data entry the increment is 0.01 mV for offset between –99.9 and 99.9 mV, and 0.1 mV for offset between –999.9 and 999.9 mV.
Referenced to the center of display graticule
Offset accuracy ±2 mV ±2% of offset setting (±1 mV ±1% typical)
Operating input voltage ±800 mV
Vertical zoom and position For all input channels, waveform memories, or functions
Vertical factor: 0.01 to 100
Vertical position: ±800 divisions maximum of zoomed waveform
Channel-to-channel crosstalk (channel isolation) ≥ 50 dB (316:1) for input frequency DC to 1 GHz
≥ 40 dB (100:1) for input frequency > 1 GHz to 3 GHz
≥ 36 dB (63:1) for input frequency > 3 GHz to ≤ 5 GHz ≥ 36 dB (63:1) for input frequency > 3 GHz to ≤ 16 GHz
Delay between channels ≤ 10 ps, typical
Between any two channels, full bandwidth, random sampling
ADC resolution 12 bits
Hardware vertical resolution 0.4 mV/LSB without averaging
Overvoltage protection ±1.4 V (DC + peak AC)
Input impedance 50 Ω ±1.5 Ω (50 Ω ±1 Ω typical)
Input match Reflections for 70 ps rise time: 10% or less Reflections for 50 ps rise time: 10% or less.
Input coupling DC
Input connectors SMA female
Internal probe power 6.0 W total maximum with PSU as supplied. N/A 6.0 W total maximum with PSU as supplied. N/A
Probe power per probe 3.3 V: 100 mA maximum
12 V: 500 mA maximum to total probe power stated above.
3.3 V: 100 mA maximum
12 V: 500 mA maximum to total probe power stated above.
Attenuation Attenuation factors may be entered to scale the oscilloscope for external attenuators connected to the channel inputs
Range: 0.0001:1 to 1 000 000:1
Units: ratio or dB
Scale: volt, watt, ampere, or unknown